Understanding the WatchMon - Telemetry - Lifetime Telemetry

Administrative screen for the WatchMon supervisor hardware, and how to understand the various fields available to read the telemetry information over the WatchMon supervisor hardware's lifetime.

Navigate to this screen via the  Telemetry option on the Menu then choosing the Lifetime tab. 

Objective

Review the total number of occurrences and the recent times when control states change from ON to OFF, etc.. The page is sorted into areas corresponding to different screens.

Field Definitions 

Critical BAttOK - count:  Total number of events when the Critical BattOK is enabled.

Critical BattOK - ON time:  Most recent time when critical BattOK control was enabled.

Critical BattOK - OFF time:   Most recent time when critical BattOK control was disabled.

Charge On - count:  Total number of events when charge high power control is enabled.

Charge On - ON time:  Most recent time when charge control was enabled.

Charge On - OFF time:  Most recent time when charge control was disabled.

Charge LimPower - count:  Total number of events when charge low/limited power control is enabled.

Charge LimPower - ON time:  Most recent time when charge control was switched to low/limited power.

Alt On - count:  Total number of events when alt charge is enabled.

Alt On - ON time:  Most recent time when alt charge control was enabled.

Alt On - OFF time:  Most recent time when alt charge control was disabled.

Discharge ON - count:  Total number of events when the discharge high power control is enabled.

Discharge ON - Recent ON time:  Most recent time when control was enabled.

Discharge ON - Recent OFF time:  Most recent time when control was disabled.

Discharge LimPower - count:  Total number of events when Discharge low/limited power control is enabled.

Discharge LimPower - ON time:  Most recent time when discharge control was switched to low/limited power.

Alt On - count:  Total number of events when alt discharge is enabled.

Alt On - ON time:  Most recent time when alt discharge control was enabled.

Alt On - OFF time:  Most recent time when alt discharge control was disabled.

Thermal Heat On - count:  Total number of events when thermal heating control is enabled.

Thermal Heat On - ON time:  Most recent time when thermal heating control was enabled. 

Thermal Heat On - OFF time:  Most recent time when thermal heating control was disabled.

Thermal Cool On - count:  Total number of events when thermal cooling control is enabled.

Thermal Cool On - ON time:  Most recent time when thermal cooling control was enabled.

Thermal Cool On - OFF time:  Most recent time when thermal cooling control was disabled.

Rule 1 - count:  Total number of events when charge high power control is enabled.

Rule 1 On - ON time:  Most recent time when charge control was enabled.

Rule 1 On - OFF time:  Most recent time when charge control was disabled.

Rule 2 On - count:  Total number of events when charge high power control is enabled.

Rule 2 On - ON time:  Most recent time when charge control was enabled.

Rule 2 On - OFF time:  Most recent time when charge control was disabled.

Rule 3 On - count:  Total number of events when charge high power control is enabled.

Rule 3 On - ON time:  Most recent time when charge control was enabled.

Rule 3 On - OFF time:  Most recent time when charge control was disabled.

Rule 4 On - count:  Total number of events when charge high power control is enabled.

Rule 4 On - ON time:  Most recent time when charge control was enabled.

Rule 4 On - OFF time:  Most recent time when charge control was disabled.

Startup:  Time stamp of most recent startup

First Sync:  Time stamp of first Sync Data 

Wizard:  Time stamp of most recent time Wizard was run.

Count Startup: Total number of events when the system has been started / powered.

Count Daily Sessions:  Total number of daily session recorded.

Count SoC% Total cycles:  total number of cycles where the battery SoC% state of charge has cycled from full to empty and returned to full threshold.

Initial Bypass:  Time when cell first went into bypass for the first time on the day.

Bypass Completed:  Time when all CellMons achieved final bypass for the day.

Bypass Extra:  Most recent partial bypass 

Bypass Test:  Time when last Bypass Test was completed.

Bypass Outcome:  Outcome of last Bypass test.  If never tested will show 'Not Tested'

SoC% Empty state:  Most recent time when the state of charge went below the empty threshold.

SoC% Full state:  Most recent time when the state of charge went above the full threshold.

SoC% Re-Cal Empty:  Most recent time when the state of charge triggered a recalibration event on empty.

SoC% Re-Cal Full:  Most recent time when the state of charge triggered a recalibration event on full.


Action button / process link events

Reset Metrics:  Ability to reset the lifetime statistics, only available in technician mode.