Expansion Output Functions
Setting | Definition | |
None | No Function selected | |
Manual On | Force relay switch to ON | |
CriticalBattOK | On when in Critical Battery OK mode. Batt happy -ON Critical - OFF |
|
Charging On | ON when charging is on |
|
Discharging On | ON when discharging is on |
|
Heating Required | ON when Heating required |
|
Cooling Required | ON when Cooling required |
|
Run/Idle input | Used for EV mostly combination of Discharging and Critical to protect from over-discharging |
|
Charge/Normal input | Used for EV mostly combination of Charging and Critical to protect from overcharging | |
Bypass Complete | ON when all cell monitors have gone into bypass complete | |
Charging Limited | ON when Charging Limited | |
Discharging Limited | ON when Discharging Limited | |
Critical Recovery | Setup to suit requirements of specific customer Do Not Use | |
Critical Pulse On | 200ms pulse sent Reverse logic of Critical Pulse OFF | |
Critical Pulse Off | 200ms pulse sent when Critical State turns to OFF used to trigger Circuit Breakers | |
Critical Fault |
Reverse logic of Critical Battery OK Batt happy - OFF Critical - ON |
|
Critical Precharge Timer | Circuit is 2 seconds - pulse relay for 2 seconds to pre-charge and it does not spark |
|
Fluid pump required | ON when either Heating or Cooling is required | |
Strip cycle discharge | Setup to suit requirements of specific customer Do Not Use |
|
Strip cycle isolate | Setup to suit requirements of specific customer Do Not Use |
|
Warning HVA charge | CV2 breached | |
Warning LVA discharge | CV11 breached | |
Charging Remote Running | ON based on control logic in remote tab. | |
Charging Off | Reverse logic of Charging ON | |
Discharging Off | Reverse logic of Discharging ON | |
Bypass Running | ON if any of the cell monitors in bypass | |
Charging Alternative | Setup based on Alternative values | |
Discharging Alternative | Setup based on Alternative values | |
Charging Strip | Setup to suit requirements of specific customer Do Not Use | |
SOC% Limit 1 | Setup based on SOC% Limits | |
SOC% Limit 2 | Setup based on SOC% Limits |
|
SOC% Limit 3 | Setup based on SOC% Limits | |
SOC% Limit 4 | Setup based on SOC% Limits | |
Reserved34 | Setup to suit requirements of specific customer Do Not Use | |
Reserved35 | Setup to suit requirements of specific customer Do Not Use | |
Reserved36 | Setup to suit requirements of specific customer Do Not Use | |
Reserved | Setup to suit requirements of specific customer Do Not Use | |