TROUBLESHOOTING: No shunt but getting shunt warning. Why?
This one is where you don't have a shunt but the WatchMon LED lights indicate SOC% Empty or SOC% full (by green or blue blinking lights)
The LED on the WatchMon is reading the values in Shunt Hardware settings. If there is no Shunt it still reads this value and if 0.0% will flicker as empty,
You can change the value so that it no longer falsely indicates by Selecting Edit then Metrics
Then when the popup screen comes up enter a new state of charge and press OK.
You then need to press save