Understanding the WatchMon - Telemetry - Daily Session History Extract
Administrative screen providing telemetry for the WatchMon supervisor hardware, and how to understand the various fields shown.
Used to retrieve the individual session summary (3650 days ~ 10 years). Method to extract all the records into a file that can be reviewed in a spreadsheet. Bulk extract to file is available when connected via USB.
Navigate to the screen via the Telemetry option on the Menu then choosing the Daily History tab and then Extract.
Start the extract process
After processing will show a subset of the collected values
Extracted text file is stored at the following path:
- My Documents \ Batrium \ Logs \ #Date# \ History_#SysCode#.txt
- #Date# is today's date
- #SysCode# is the system code
The file format is appended with fields stored in tab delimited columns.
- LogID #
- LogDate yyyy-MM-dd
- LogTime HH:mm:ss
- CriticalEvents #
- MinCellVolt Volt
- MaxCellVolt Volt
- MinThermal ºC
- MaxThermal ºC
- MinSoc % Percent
- MaxSoc % Percent
- MinShuntVolt Volt
- MaxShuntVolt Volt
- MinSupplyVolt Volt
- MaxSupplyVolt Volt
- PeakAmpCharge Amp
- PeakAmpDischg Amp
- CumulAhCharge Ah
- CumulAhDischg Ah
- SocBand-A hour
- SocBand-B hour
- SocBand-C hour
- SocBand-D hour
- SocBand-E hour
- SocBand-F hour
- SocBand-G hour
- SocBand-H hour
- ThermalBand-A hour
- ThermalBand-B hour
- ThermalBand-C hour
- ThermalBand-D hour
- ThermalBand-E hour
- ThermalBand-F hour
- ThermalBand-G hour
- ThermalBand-H hour